Step 2.
When the prompt Press F3 to restore to primary is displayed, press F3 to start the server from the
primary bank.

Nx boot failure

Configuration changes, such as added devices or adapter firmware updates, and firmware or application
code problems can cause the server to fail POST (the power-on self-test).
If this occurs, the server responds in either of the following ways:
• The server restarts automatically and attempts POST again.
• The server hangs, and you must manually restart the server for the server to attempt POST again.
After a specified number of consecutive attempts (automatic or manual), the Nx boot failure feature causes
the server to revert to the default UEFI configuration and start the Setup utility so that you can make the
necessary corrections to the configuration and restart the server. If the server is unable to successfully
complete POST with the default configuration, there might be a problem with the system board.
To specify the number of consecutive restart attempts that will trigger the Nx boot failure feature, in the
Setup utility, click System Settings ➙ Operating Modes ➙ POST Attempts Limit. The available options
are 3, 6, 9, and 255 (disable Nx boot failure).

Solving power problems

Use this information to solve power problems.
Power problems can be difficult to solve. For example, a short circuit can exist anywhere on any of the power
distribution buses. Usually, a short circuit will cause the power subsystem to shut down because of an
overcurrent condition. To diagnose a power problem, use the following general procedure:
Step 1.
Turn off the server and disconnect all ac power cords.
Step 2.
Check the power-fault LEDs on the system board (see
Step 3.
Check the LEDs on the operator information panel (see
Step 4.
Check for loose cables in the power subsystem. Also check for short circuits, for example, if a
loose screw is causing a short circuit on a circuit board.
Step 5.
Remove the adapters and disconnect the cables and power cords to all internal and external
devices until the server is at the minimum configuration that is required for the server to start (see
"Power-supply LEDs" on page 391
Step 6.
Reconnect all ac power cords and turn on the server. If the server starts successfully, reseat the
adapters and devices one at a time until the problem is isolated.
If the server does not start from the minimum configuration, see
the components in the minimum configuration one at a time until the problem is isolated.

Solving Ethernet controller problems

The method that you use to test the Ethernet controller depends on which operating system you are using.
See the operating-system documentation for information about Ethernet controllers, and see the Ethernet
controller device-driver readme file.
Try the following procedures:
"System-board LEDs" on page
"Operator information panel" on page
for the minimum configuration).
"Power problems" on page 373
21).
11).