1. Check the IBM support website for an applicable retain tip or firmware update that applies to this
memory error. 2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or
the event logs) to a different memory channel or microprocessor. 3. If the error still occurs on the
same DIMM, replace the affected DIMM. 4. (Trained technician only) If the problem occurs on the
same DIMM connector, check the DIMM connector. If the connector contains any foreign material or
is damaged, replace the system board. 5. (Trained technician only) Remove the affected
microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is
found, replace the system board. 6. (Trained technician only) Replace the affected microprocessor.
• 806f050c-2581xxxx : Memory Logging Limit Reached for [PhysicalMemoryElementName] on
Subsystem [MemoryElementName]. (All DIMMS)
This message is for the use case when an implementation has detected that the Memory Logging Limit
has been Reached.
May also be shown as 806f050c2581xxxx or 0x806f050c2581xxxx
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0144
User Response
1. Check the IBM support website for an applicable retain tip or firmware update that applies to this
memory error. 2. Swap the affected DIMMs (as indicated by the error LEDs on the system board or
the event logs) to a different memory channel or microprocessor. 3. If the error still occurs on the
same DIMM, replace the affected DIMM. 4. (Trained technician only) If the problem occurs on the
same DIMM connector, check the DIMM connector. If the connector contains any foreign material or
is damaged, replace the system board. 5. (Trained technician only) Remove the affected
microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is
found, replace the system board. 6. (Trained technician only) Replace the affected microprocessor.
One of the DIMMs :
• 806f050d-0400xxxx : Array [ComputerSystemElementName] is in critical condition. (Drive 0)
This message is for the use case when an implementation has detected that an Array is Critical.
May also be shown as 806f050d0400xxxx or 0x806f050d0400xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
.
Chapter 3
Diagnostics
163