• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
Chapter 4 "Parts listing, Lenovo System x3550 M3 Type 4254 and 7944" on page 403
• See
components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
• If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
• Go to the IBM support website at
tips, and new device drivers or to submit a request for information.
Description
Error code
3808003
Error retrieving system configuration from
IMM
3808004
IMM system event log full
3818001
Core Root of Trust Measurement (CRTM)
update failed
3818002
Core Root of Trust Measurement (CRTM)
update aborted
3818003
Core Root of Trust Measurement (CRTM)
flash lock failed
3818004
Core Root of Trust Measurement (CRTM)
system error
3818005
Current Bank Core Root of Trust
Measurement (CRTM) capsule signature
invalid
http://www.ibm.com/supportportal/
Action
• When using out-of-band, use the IMM Web
• When using the local console:
to check for technical information, hints,
1. Shut down the system and remove the power
cords from the server; then, reconnect the server
to power and restart it.
2. Run the Setup utility and select Save Settings.
3. Update the IMM firmware to the latest level (see
"Updating the firmware" on page
interface or IPMItool to clear the logs from the
operating system.
1. Run the Setup utility.
2. Select System Event Log ➙ Clear System
Event Log.
3. Restart the server.
1. Run the Setup utility, select Load Default
Settings, and save the settings.
2. (Trained service technician only) Replace the
system board.
1. Run the Setup utility, select Load Default
Settings, and save the settings.
2. (Trained service technician only) Replace the
system board.
1. Run the Setup utility, select Load Default
Settings, and save the settings.
2. (Trained service technician only) Replace the
system board.
1. Run the Setup utility, select Load Default
Settings, and save the settings.
2. (Trained service technician only) Replace the
system board.
1. Run the Setup utility, select Load Default
Settings, and save the settings.
2. (Trained service technician only) Replace the
system board.