Lenovo System x3550 M3 Problem Determination And Service Manual page 87

Table of Contents

Advertisement

This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 8007020f2582xxxx or 0x8007020f2582xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0522
User Response
Complete the following steps for PCI I/O resource error issue resolution: 1. Understand the I/O
resource requirements in a basic system. 2. Identify the I/O resource requirements for desired add-in
adapters. For examples, PCI-X or PCIe adapters. 3. Disable on-board devices that you can do
without and that request I/O. 4. In F1 setup, select the System Settings then Device and I/O Ports
menu. 5. Remove adapters or disable slots until the I/O resource is less than 64 KB.
• 80070219-0701xxxx : Sensor [SensorElementName] has transitioned to critical from a less severe
state. (Sys Board Fault)
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 800702190701xxxx or 0x800702190701xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0522
User Response
1. Check the system-event log. 2. Check for an error LED on the system board. 3. Replace any failing
device. 4. Check for a server firmware update. Important: Some cluster solutions require specific
code levels or coordinated code updates. If the device is part of a cluster solution, verify that the
latest level of code is supported for the cluster solution before you update the code. 5. (Trained
technician only) Replace the system board.
.