Figure 59. ServeRAID controller installation
Step 7.
Install the SAS/SATA RAID riser-card assembly (see
assembly" on page
Step 8.
Route the signal cables from the drive backplane over the blue adapter retention bracket.
Step 9.
Connect the signal cables to the SAS/SATA adapter:
• ServeRAID-BR10il v2 adapter: Take the signal cable that is attached to the drive backplane for
drive bays 0 through 3 and connect it to the SAS/SATA connector on the ServeRAID adapter.
Figure 60. ServeRAID-BR10il v2 adapter cable connection
• ServeRAID-BR10i, ServeRAID-M1015, ServeRAID-M5014, or ServeRAID-M5015 adpater:
Take the signal cable that is attached to the drive backplane for drive bays 4 through 7 and
connect it to the ServeRAID adapter connector that is closest to the power supply cage.
Connect the other signal cable so that is attached to the drive backplane for drive bays 0
through 3 and connect it to the other connector on the adapter.
451).
"Installing the SAS/SATA RAID riser-card
.
Chapter 5
Removing and replacing components
455