12
CIM Information
Prefix: PLAT ID: 0490
User Response
1. Reduce the temperature. 2. Check the server airflow. Make sure that nothing is blocking the air
from coming into or preventing the air from exiting the server.
• 80010901-0c01xxxx : Numeric sensor [NumericSensorElementName] going high (upper critical)
has asserted. (Ambient Temp)
This message is for the use case when an implementation has detected an Upper Critical sensor going
high has asserted.
May also be shown as 800109010c01xxxx or 0x800109010c01xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0494
User Response
1. Reduce the ambient temperature. 2. Check the server airflow. Make sure that nothing is blocking
the air from coming into or preventing the air from exiting the server.
• 80010902-0701xxxx : Numeric sensor [NumericSensorElementName] going high (upper critical) has
asserted. (Planar 12V)
This message is for the use case when an implementation has detected an Upper Critical sensor going
high has asserted.
May also be shown as 800109020701xxxx or 0x800109020701xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Voltage
SNMP Trap ID
1
CIM Information
Prefix: PLAT ID: 0494
.