Lenovo System x3550 M3 Problem Determination And Service Manual page 134

Table of Contents

Advertisement

• 806f020d-0400xxxx : Failure Predicted on drive [StorageVolumeElementName] for array
[ComputerSystemElementName]. (Drive 0)
This message is for the use case when an implementation has detected an Array Failure is Predicted.
May also be shown as 806f020d0400xxxx or 0x806f020d0400xxxx
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0168
User Response
1. Run the hard disk drive diagnostic test on drive n. 2. Reseat the following components: a. Hard disk
drive b. Cable from the system board to the backplane. 3. Replace the following components one at a
time, in the order shown, restarting the server each time: a. Hard disk drive. b. Cable from the system
board to the backplane. c. Hard disk drive backplane. (n = hard disk drive number)
• 806f020d-0401xxxx : Failure Predicted on drive [StorageVolumeElementName] for array
[ComputerSystemElementName]. (Drive 1)
This message is for the use case when an implementation has detected an Array Failure is Predicted.
May also be shown as 806f020d0401xxxx or 0x806f020d0401xxxx
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0168
User Response
1. Run the hard disk drive diagnostic test on drive n. 2. Reseat the following components: a. Hard disk
drive b. Cable from the system board to the backplane. 3. Replace the following components one at a
time, in the order shown, restarting the server each time: a. Hard disk drive. b. Cable from the system
board to the backplane. c. Hard disk drive backplane. (n = hard disk drive number)
System x3550 M3Problem Determination and Service Guide
122

Advertisement

Table of Contents
loading

This manual is also suitable for:

42547944

Table of Contents