Lenovo System x3550 M3 Problem Determination And Service Manual page 201

Table of Contents

Advertisement

Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0240
User Response
1. Check the system-event log. 2. (Trained technician only) Remove the failing microprocessor from
the system board (see Removing a microprocessor and heat sink). 3. Check for a server firmware
update. Important: Some cluster solutions require specific code levels or coordinated code updates.
If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster
solution before you update the code. 4. Make sure that the two microprocessors are matching. 5.
(Trained technician only) Replace the system board.
• 806f0823-2101xxxx : Watchdog Timer interrupt occurred for [WatchdogElementName]. (Watchdog)
This message is for the use case when an implementation has detected a Watchdog Timer interrupt
occurred.
May also be shown as 806f08232101xxxx or 0x806f08232101xxxx
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0376
User Response
No action; information only.
• 806f0a07-0301xxxx : [ProcessorElementName] is operating in a Degraded State. (CPU 1)
This message is for the use case when an implementation has detected a Processor is running in the
Degraded state.
May also be shown as 806f0a070301xxxx or 0x806f0a070301xxxx
Severity
Warning
Serviceable
.
Chapter 3
Diagnostics
189

Advertisement

Table of Contents
loading

This manual is also suitable for:

42547944

Table of Contents