Omron ZW-8000 Series User Manual page 34

Confocal fiber type displacement sensor
Table of Contents

Advertisement

Installation precautions
Use flat head screws.
Fix it within the shaded area in the figure below.
Tightening torque: 0.15 N · m (M2 screw) or 0.5 N · m (M3 screw)
● ZW-SP Series
35.4
22.1
35.4
22.1
Important
• When tightened outside of the shaded area, damage may occur.
• Adjust settings while visually checking the position and brightness of a spot on an object with diffuse reflection.
When measuring on a high-reflectivity object, such as a mirror or wafer, visual check may be difficult.
Additionally, the measurement value which set out of the measurement region may be output.
Basic precautions for installation
Do not install the Sensor Head in a place where strong light hits the laser emitter/receiver section of the Sensor
Head. Also, if an object has a shiny surface, the light from the lighting will be reflected and a malfunction may
occur. In such a case, prevent reflection by, for example, covering the light to stop reflection.
These precautions apply to all sensor head types and all installation methods.
32
Basic Operations for Displaying Measurement Results
● ZW-SPR Series
41.4
28.1
41.4
28.1
ZW-8000/7000/5000
User's Manual

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Zw-7000 seriesZw-5000 series

Table of Contents