Omron ZW-8000 Series User Manual page 247

Confocal fiber type displacement sensor
Table of Contents

Advertisement

Setting the Differentiation Filter
Setting the Differentiation Filter p.159
As an example, here is an explanation of the procedure for selecting the "200 μs" number of differential cycles.
Operating procedure
Steps
Key operation
1 to 4
For moving to "FILTER", see steps 1 to 4 in p.242.
5
6
7
8
9
ZW-8000/7000/5000
User's Manual
Display
Description
Select "DIFFER" as the filter type.
Press the
key.
Enable the differentiation filter.
The current setting value is displayed on the sub-display.
Press
Select "ON", then press the
Set the number of differential cycles.
"CYCLE" is displayed on the main display and the current setting
value is displayed on the sub-display.
Press
blinks.
To edit numerical values, use the
In this example, input "10", then press the
The decimal point is displayed.
Press the
Determine the decimal point and then press the
Press and hold the
RUN mode.
To save the setting, refer to "7-3 Functions of Operating Keys"
(p.222).
/
keys to select "DIFFER" and press the
/
key to enter editing mode and the sub-display blinks.
key.
key to enter the editing mode, and the sub-display
/
/
key to move the decimal point.
key for two seconds or more to enter the
Setting the Output Conditions
/
/
keys.
key.
key.
245

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Zw-7000 seriesZw-5000 series

Table of Contents