Omron ZW-8000 Series User Manual page 172

Confocal fiber type displacement sensor
Table of Contents

Advertisement

Setting the Offset
Set this item to set the reference value by a zero reset to a value other than zero.
Item
Setting item
Zero reset
Offset
 Multi View Explore
→ Edit pane
→ Task Settings window : [Zero reset]
1
Set [Status] to ON.
Setting the Status p.169
Important
Offset can be set only when [Status] is set to ON.
2
Enter an offset value at [Zero reset] - [Offset].
Note
The offset can also be set by the operating keys on the Sensor Controller.
Setting the Offset p.257
170
Setting the Output Conditions
Setting value
-999.999999 to 999.999999 [mm]
(default value: 0)
: [Bank Group] | [(Bank Data Name)] (double click)
: [Task Settings] icon (
Description
Set the offset value.
)
ZW-8000/7000/5000
User's Manual

Advertisement