Omron ZW-8000 Series User Manual page 164

Confocal fiber type displacement sensor
Table of Contents

Advertisement

Hold clearing conditions
Held values can be cleared by the following operation.
• When FUNC (adjustment) mode/RUN (operation) mode is switched
• When hold RESET is entered (32-pole extension connector,
• Hold RESET command is entered.
(Example) Peak
The mode is switched between
the FUNC mode and RUN mode
FUNC mode
Clamp level
(Example) Auto Peak
The mode is switched between
the FUNC mode and RUN mode
FUNC mode
Clamp level
Important
If an abnormal measured value is obtained, the hold value is cleared. To not clear the hold value even if an abnormal
measured value is obtained, set "KEEP" as the non-measurement setting.
"2-1 Parallel I/O connection" described in Displacement Sensor ZW-8000/7000/5000 series Confocal
Fiber Type Displacement Sensor User's Manual for Communications Settings (Z363)
162
Setting the Output Conditions
RUN mode
When RESET is executed
(32-pole extension connector/key input/command).
Sampling
Sampling
RUN mode
When RESET is executed
(32-pole extension connector/key input/command).
key)
When the hold value is reset,
the clamp level is output until
the next hold value is applied.
Hold value
Measurement
value
Hold value
Measurement
value
ZW-8000/7000/5000
User's Manual