Omron ZW-8000 Series User Manual page 221

Confocal fiber type displacement sensor
Table of Contents

Advertisement

Data output
I/O setting
setting
[I/O]
[COM.OUT]
(cont'd)
Condition for
measurement state
[MS.CON]
Bank setting
[BANK]
System
Sensor head
setting
Calibration
[SYSTEM]
[H.CALIB]
Save
[SAVE]
Initialization
[INIT]
Synchronous
measurement
mode
[TRIGER]
Extension fiber
cable length
[CABLE]
Internal logging
setting
[LOGING]
ZW-8000/7000/5000
User's Manual
Bank change
[BK.CHG]
Bank mode
[BK.MODE]
Bank copy
[BK.COPY]
Bank clear
[BK.CLR]
The grayed-out settings can only be used with ZW-8000@.
Setting
Option/Setting Range
Data output
Off [OFF]*/Ethernet[ETN]/
destination
RS232C[RS232C]
[OUTPUT]*
Output data
format
ASCII[ASCII]*/Binary[BINARY]
[FORMAT]
Number of
integer digits
1 / 2 / 3 / 4 /5*
[INT.NUM]
Fractional
digits
0 / 1 / 2 / 3 / 4 / 5 / 6*
[DEC.NUM]
Leading zeros
suppressed
Off* /On
[ZEROSP]
None [NO]*/Comma [COMMA]/
Field
Tab [TAB]/Space [SPACE]/
separator
CR[CR]/LF[LF]/CR+LF[CRLF]/
[FIELD]
Semicolon [SEMICO]
None [NO]*/Comma [COMMA]/
Record
Tab [TAB]/Space [SPACE]/
separator
CR[CR]/LF[LF]/CR+LF[CRLF]/
[RECORD]
Semicolon [SEMICO]
0 surface [0EDGE]/1surface [1EDGE] / 2
Number of
Edge
surface[2EDGE] /3 surface [3EDGE/ 4
[SFC.NUM]
surface[4EDGE] /Edge 5 or more[5ED.OVR]
Equal to the specified number of
Condition for
Edge[EQRL]/Greater than the specified
number of Edge
number of Edge[GRT.THN]/ Less than the
[SFC.CON]
specified number of Edge[LES.THN]
Bank1 [BANK1] to Bank8 [BANK8]
Bank number
(default value: Bank1) Up to Bank32
[BANK]
can be selected when the bank mode
is "Judgment value".
Bank mode
Normal [NORMAL]*/
[BK.MODE]
Judgment value [JUDGE]
Copy source
Bank1 [BANK1] to Bank8 [BANK8]
[FROM]
Copy destination
Bank1 [BANK1] to Bank8 [BANK8]
[TO]
Bank clear
Ok [OK]/Cancel [CAN]
[BK.CLR]
Sensor head
calibration
OK [OK]/Cancel [CAN]
[H.CALIB]
Save
OK [OK]/Cancel [CAN]
[SAVE]
Initialization
OK [OK]/Cancel [CAN]
[INIT]
Synchronous
Internal synchronous measurement mode
measurement
[AUTO]* /External synchronous measurement
mode
mode [PARA.IN] /PDO synchronous
[TRIGER]
measurement mode [ECT.PDO]
Extension fiber
NONE [NONE]*/2m[2M]/
cable length
5m[5M]/10m[10M]/
[CABLE]
20m[20M]/30m[30M]
Save interval
0 to 1000 (default value: 1)
[INTRVL]
Save count
0 to 999999 (default value: 100000)
[COUNT]
Output data format
ASCII [ASCII]*/ Binary [BINARY]
[FORMAT]
Overwrite mode
Off [OFF]*/On [ON]
[OVR.WRT]
Label insert mode
Off [OFF]*/On [ON]
[LABEL]
Search from Menu Tree
* default value
Pages
p.260
p.261
p.262
p.264
p.270
p.263
p.271
p.96
p.273
p.114
p.114
p.114
p.114
p.114
219

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Zw-7000 seriesZw-5000 series

Table of Contents