Omron ZW-8000 Series User Manual page 103

Confocal fiber type displacement sensor
Table of Contents

Advertisement

Example 3: Measure the level difference of the sensing object (execute zero reset at every measurement)
Sensor head
This step is
measured.
Zero reset
Zero reset
executed
executed
Direction of movement
The zero reset function also allows setting the reference value to the hold value for a hold measurement or any
value other than zero.
Setting the Zero Reset p.169 p.256
Executing Zero Reset
1
Place the reference sensing object in
position.
2
Press the
key.
The ZERO indicator illuminates and the current
measured value is registered as 0.
ZW-8000/7000/5000
User's Manual
Zero reset
executed
Perform the Zero Reset
101