Important
• When a zero reset is executed, the analog output becomes the voltage or current value at the center of the two
preset points. Analog output becomes roughly 0 V or 12 mA when focus is not set.
"2-1 Parallel I/O connection" described in Displacement Sensor ZW-8000/7000/5000 series Confocal
Fiber Type Displacement Sensor User's Manual for Communications Settings (Z363)
• The Zero Reset function can also be executed by supplying a ZERO signal to the 32-pole extension connector.
32-pole extension connector p.78
"2-1 Parallel I/O connection" described in Displacement Sensor ZW-8000/7000/5000 series Confocal
Fiber Type Displacement Sensor User's Manual for Communications Settings (Z363)
• The Zero Reset function can also be executed by turning ON the EtherCAT ZERO input signal.
"3-1 EtherCAT Connection" described in Displacement Sensor ZW-8000/7000/5000 series Confocal
Fiber Type Displacement Sensor User's Manual for Communications Settings (Z363)
Canceling Zero Reset
1
Press and hold the
seconds.
Important
• The Zero Reset function can also be executed by supplying a ZERO signal to the 32-pole extension connector.
32-pole extension connector p.78
"2-1 Parallel I/O connection" described in Displacement Sensor ZW-8000/7000/5000 series Confocal
Fiber Type Displacement Sensor User's Manual for Communications Settings (Z363)
• The canceling Zero Reset function can also be executed by turning ON the EtherCAT ZEROCLR input signal.
"3-1 EtherCAT Connection" described in Displacement Sensor ZW-8000/7000/5000 series Confocal
Fiber Type Displacement Sensor User's Manual for Communications Settings (Z363)
102
Perform the Zero Reset
key for two
ZW-8000/7000/5000
User's Manual