Omron ZW-8000 Series User Manual page 177

Confocal fiber type displacement sensor
Table of Contents

Advertisement

Item
Setting item
Judgment
LOW threshold
HIGH threshold
 Multi View Explore
→ Edit pane
→ Task settings window : [Judgment]
1
Enter the [LOW threshold] and [HIGH thresh-
old].
Important
• Hysteresis (hysteresis width) can also be set to threshold values. Set hysteresis when measured values are
dispersed around a threshold value, and judgments are unstable, to prevent chattering.
"2-1 Parallel I/O connection" described in Displacement Sensor ZW-8000/7000/5000 series Confocal
Fiber Type Displacement Sensor User's Manual for Communications Settings (Z363)
• Threshold values can also be adjusted by directly entering values in the RUN mode.
This helps you to make fine adjustments without shutting down the system.
Changing Threshold Values p.228
Note
Threshold Value Settings can also be set by the operating keys on the Sensor Controller.
7-10 Setting Threshold Value p.265
ZW-8000/7000/5000
User's Manual
Setting value
- 999.999999 to 999.999999 [mm]
Factory default differs depending on the con-
nected Sensor Head.
- 999.999999 to 999.999999 [mm]
: [Bank Group] | [(Bank Data Name)] (double click)
: [Task Settings] icon (
Description
Set the lower limit (LOW) threshold value.
Set the upper limit (HIGH) threshold value.
)
Setting Threshold Value