Setting the Zero Reset Type
Set the zero reset type.
Item
Setting item
Zero reset
Type
 Multi View Explore
→ Edit pane
→ Task Settings window : [Zero reset]
1
Set [Status] to ON.
Setting the Status p.169
Important
The zero reset type can be set only when [Status]
is set to ON.
2
Select the zero reset type from [Type].
Note
The zero reset type can also be set by the operating keys on the Sensor Controller.
Setting the Zero Reset Mode p.258
ZW-8000/7000/5000
User's Manual
Setting value
Description
Real value
Sets the measured value when a zero reset is executed to zero.
Sensor head
Zero reset
Hold value
Sets the measured value (hold value) when a zero reset is executed to zero.
This is enabled when hold measurement is performed.
Sensor head
: [Bank Group] | [(Bank Data Name)] (double click)
: [Task Settings] icon (
Measurement of height
from reference surface
Reference A
Hold A
(reference)
Zero reset
Direction of movement
)
Setting the Output Conditions
Measurement of height
from reference surface
171