Performing Internal Logging with Parallel I/O

The logging start and end timings can be specified using LOGGING input signals from parallel I/O. When doing
so, follow the procedure below to set the data logging conditions.
 Multi view Explore
→ Edit pane
→ Sensor settings window
1
Set the logging conditions for internal logging.
There are three settings: Number of logging, number of logging decimation, and overwrite mode.
Item
Setting item
Internal logging
Number of
setting
logging data
Internal logging
settings
Overwrite mode
Label insert
mode
LOGERR signal is turned ON at the following cases:
• Overwrite mode is OFF
• 2,000,000 items have already been logged in the internal memory at the beginning of logging.
To continue to log regardless of the logging count while LOGGING input signal is turned ON, set as
below:
• Number of logging data: 0
• Overwrite mode: ON
When the number of loggings reaches 2,000,000, past logging data is overwritten and logging continues
on the latest data.
Overwrite mode and label insert mode cannot be used at the same time.
2
Set the output conditions of internal logging data.
Set the conditions for the external output using the non-procedural command LO.
Item
Setting item
Internal logging
Output data
setting
format
ZW-8000/7000/5000
User's Manual
: [System] (double-click)
: [Sensor Settings] icon (
: [Internal logging setting]
Setting value
Description
0 to 2000000
Set the number of data to save for each internal logging
(default value: 100000)
output data.
0 to 1000
Set the interval of saving internal logging data.
(default value: 1)
If 1 is set, all data is saved. If 2 is set, one measured data is
saved every two measurements.
If 0 is set, data is saved only when the hold value is applied.
OFF (default value)/ON
Set whether to make the internal logging mode run in
overwrite mode.
Sets the operation to be performed when the logging count
exceeds the set number of logging data.
OFF: Internal logging is stopped.
ON: The oldest logging data is overwritten.
OFF (default value)/ON
Set the operation to be performed when logging input is
turned on.
OFF: No operation.
ON: When logging input is turned on, inserts label into log-
ging data.
Setting value
Description
ASCII (default value)/
Select the output format for outputting internal logging data.
Binary
)
Performing internal logging
117