Omron ZW-8000 Series User Manual page 156

Confocal fiber type displacement sensor
Table of Contents

Advertisement

Setting the Average Filter
Output measured data as the average value of a preset count.
This is set in cases such as to reduce the fluctuation of measurement values and increase the static resolution.
Item
Setting item
Average number
Average
of times
 Multi View Explore
→ Edit pane
→ Task Settings window : [Filter]
1
Select how many times the latest measured
values are to be averaged before output from
[Average].
Important
When measurement is started, the measurement result is not updated and output until the measured values have
been sampled for the preset average count.
Note
The average filter can also be set by the operating keys on the Sensor Controller.
Setting the Average Filter p.243
154
Setting the Output Conditions
Setting value
• Internal synchronous measurement mode
1/2/4/8/16/32/64/128/256/512/1024(default value)/2048/4096/
8192/16384 [times]
• External/PDO synchronous measurement mode
1(default value)/2/4/8/16/32/64/128/256/512/1024/2048/4096/
8192/16384 [times]
: [Bank Group] | [(Bank Data Name)] (double click)
: [Task Settings] icon (
Description
Switches the average count.
)
ZW-8000/7000/5000
User's Manual