Cumulative Encoder Out Pulses (Obj. 2B16H)]; [Cumulative Encoder Out Pulses (Obj. 2B16H: 00H)]; Temperature Of Motor Thermistor (Obj. 2B17H)]; [Temperature Of Motor Thermistor (Obj. 2B17H: 00H)] - Mitsubishi Electric MR-J5-G-N1 User Manual

Hide thumbs Also See for MR-J5-G-N1:
Table of Contents

Advertisement

8.18

[Cumulative encoder out pulses (Obj. 2B16h)]

[Cumulative encoder out pulses (Obj. 2B16h: 00h)]

Data Type
Access
I32
RO
Supported firmware version
ECT
A5
Description
The A/B-phase pulse output feedback total value is returned.
The returned value is limited within the range from C4653601h (-999999999) to 3B9AC9FFh (999999999). If the value
exceeds the upper or lower limit value, it changes to "00000000h".
8.19

[Temperature of motor thermistor (Obj. 2B17h)]

[Temperature of motor thermistor (Obj. 2B17h: 00h)]

Data Type
Access
I16
RO
Supported firmware version
ECT
A5
Description
The temperature of the servo motor thermistor is returned.
8.20
[Motor-side cumu. feedback pulses (before gear)
(Obj. 2B18h)]
[Motor-side cumu. feedback pulses (before gear) (Obj. 2B18h:
00h)]
Data Type
Access
I32
RO
Supported firmware version
ECT
A5
Description
The servo motor-side cumulative feedback pulses (before gear) (motor unit) are returned.
The returned value is limited within the range from C4653601h (-999999999) to 3B9AC9FFh (999999999). If the value
exceeds the upper or lower limit value, it changes to "00000000h".
8 Monitor Objects
90
8.18 [Cumulative encoder out pulses (Obj. 2B16h)]
Mapping
Default
TxPDO
Mapping
Default
TxPDO
Mapping
Default
TxPDO
Range
Units
80000000h to
pulse
7FFFFFFFh
Range
Units
8000h to 7FFFh
°C
Range
Units
80000000h to
pulse
7FFFFFFFh
Save
Parameter
Impossible
Save
Parameter
Impossible
Save
Parameter
Impossible

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-j5w-g-n1Mr-j5-gMr-j5w-g