[Auxiliary (Obj. 2801h: 06h)]

Data Type
Access
I32
RW
Supported firmware version
ECT
B8
Description
Set the auxiliary function of the point table.
Setting "1" or "3" for the last point table triggers an alarm.
• Absolute position command method
0: Execute the automatic operation of one selected point table.
1: Execute the automatic continuous operation without stopping the next point table.
8: Execute the automatic continuous operation without stopping the point table selected at startup.
9: Execute the automatic continuous operation without stopping the point table No.1.
• Relative position command method
2: Execute the automatic operation of one selected point table.
3: Execute the automatic continuous operation without stopping the next point table.
10: Execute the automatic continuous operation without stopping the point table selected at startup.
11: Execute the automatic continuous operation without stopping the point table No.1.

[M code (Obj. 2801h: 07h)]

Data Type
Access
I32
RW
Supported firmware version
ECT
B8
Description
Set the code to be outputted when the positioning operation is completed.
Mapping
Default
Impossible
0
Mapping
Default
Impossible
0
Range
Units
0 to 3, 8 to 11
Range
Units
0 to 255
16.1 [Point table 001 (Obj. 2801h)]
Save
Parameter
Possible
Point table
Save
Parameter
Possible
Point table
16 Point table Mode Objects
16