3.7
[Restore default parameters (Obj. 1011h)]
[Restore default parameters (Obj. 1011h: 00h)]
Data Type
Access
U8
RO
Supported firmware version
ECT
A5
Description
The total number of Sub Indexes is returned.
Default
Range
01h
01h (fixed)
[Restore all default parameters (Obj. 1011h: 01h)]
Data Type
Access
U32
RW
Supported firmware version
ECT
A5
Description
All parameters (servo parameters, network parameters, and point table data) that can be stored in the non-volatile memory
can be reset to the factory setting. To reset the servo parameters and network parameters to the factory setting, write
"64616F6Ch" (= reverse order of ASCII code of "load") in this object, and cycle the power or reset the software.
When a multi-axis servo amplifier is used, the servo parameters of all axes are initialized.
The read value is always "00000001h" (initializing values).
Mapping
Default
Impossible
Description
Sub Index 1 is supported.
Mapping
Default
Impossible
00000001h
Range
Units
Range
Units
00000000h to
FFFFFFFFh
3.7 [Restore default parameters (Obj. 1011h)]
Save
Parameter
Impossible
Save
Parameter
Impossible
3 General Objects
3