Vibration Based Fault Prediction Threshold (Obj. 2C2Dh)]; [Vibration Based Fault Prediction Threshold (Obj. 2C2Dh: 00H)]; Vibration Based Fault Prediction Prepare Status (Obj. 2C2Eh)]; [Vibration Based Fault Prediction Prepare Status (Obj. 2C2Eh: 00H)] - Mitsubishi Electric MR-J5-G-N1 User Manual

Hide thumbs Also See for MR-J5-G-N1:
Table of Contents

Advertisement

9.20
[Vibration based fault prediction threshold (Obj.
2C2Dh)]

[Vibration based fault prediction threshold (Obj. 2C2Dh: 00h)]

Data Type
Access
I32
RO
Supported firmware version
ECT
A5
Description
The threshold for vibration failure prediction is returned.
9.21
[Vibration based fault prediction prepare status
(Obj. 2C2Eh)]
[Vibration based fault prediction prepare status (Obj. 2C2Eh:
00h)]
Data Type
Access
I16
RO
Supported firmware version
ECT
A5
Description
The preparation progress for vibration failure prediction is returned.
9.22

[Machine total distance (Obj. 2C2Fh)]

[Machine total distance (Obj. 2C2Fh: 00h)]

Data Type
Access
U32
RO
Supported firmware version
ECT
A5
Description
The machine total travel distance is returned.
9 Manufacturer Specific Control Object
110

9.20 [Vibration based fault prediction threshold (Obj. 2C2Dh)]

Mapping
Default
Impossible
Mapping
Default
Impossible
Mapping
Default
Impossible
Range
Units
-2147483648 to
0.1 %
2147483647
Range
Units
0 to 100
%
Range
Units
00000000h to
rev
FFFFFFFFh