7.2
[Alarm history _1 (Obj. 2A01h)] - [Alarm history
_15 (Obj. 2A0Fh)]
The second (2A01h) to 16th (2A0Fh) latest alarm information of the alarm history is returned. The description of each Sub
Index is the same as that of [Alarm history newest (Obj. 2A00h)].
Page 72 [Alarm history newest (Obj. 2A00h)]
7.3

[Clear alarm history (Obj. 2A40h)]

[Clear alarm history (Obj. 2A40h: 00h)]

Data Type
Access
U16
RW
Supported firmware version
ECT
A5
Description
Writing "1EA5h" clears the alarm history.
When the object is read, "0000h" is returned.
7.4

[Current alarm (Obj. 2A41h)]

[Current alarm (Obj. 2A41h: 00h)]

Data Type
Access
U32
RO
Supported firmware version
ECT
A5
Description
The latest alarm that has occurred in the servo amplifier is returned. When no alarm has occurred, "00000000h" is returned.
Bit 0 to Bit 15: Alarm detail number
Bit 16 to Bit 31: Alarm number
For example, if [AL. 538.1] occurs, "05380001h" is returned.
Mapping
Default
Impossible
0000h
Mapping
Default
TxPDO
00000000h

7.2 [Alarm history _1 (Obj. 2A01h)] - [Alarm history _15 (Obj. 2A0Fh)]

Range
Units
0000h to FFFFh
Range
Units
00000000h to
FFFFFFFFh
Save
Parameter
Impossible
Save
Parameter
Impossible
7 Alarm Objects