Mitsubishi Electric MR-J5-G-N1 User Manual page 145

Hide thumbs Also See for MR-J5-G-N1:
Table of Contents

Advertisement

■[Bit 9: OMS]
Setting value
Symbol
1 (pp)
Change on
set-point
3 (pv)
4 (tq)
6 (hm)
8 (csp)
9 (csv)
10 (cst)
*1
-100 (jg)
*1
-101 (pt)
*1 Available on servo amplifiers with firmware version B8 or later.
Description
Enabled only in Set of set-points (when the bit 5 of [Obj. 6040h: 00h] is "0").
0: Shifts to the next positioning after completing the current positioning.
1: Shifts to the next positioning after performing positioning up to the current set-point with the setting of [profile velocity
(Obj. 6081h)].
10 PDS Control Objects
10.2 [Controlword (Obj. 6040h)]
11
143

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-j5w-g-n1Mr-j5-gMr-j5w-g

Table of Contents