Unit Power Consumption 2 (Obj. 2B43H)]; [Unit Power Consumption 2 (Obj. 2B43H: 00H)]; Converter Regenerative Load Ratio (Obj. 2B49H)]; [Converter Regenerative Load Ratio (Obj. 2B49H: 00H)] - Mitsubishi Electric MR-J5-G-N1 User Manual

Hide thumbs Also See for MR-J5-G-N1:
Table of Contents

Advertisement

8.39

[Unit power consumption 2 (Obj. 2B43h)]

[Unit power consumption 2 (Obj. 2B43h: 00h)]

Data Type
Access
I32
RO
Supported firmware version
ECT
A5
Description
For the MR-J5-_G_/MR-J5W_-_G_, the unit power consumption is returned.
For the MR-J5D_, the power consumption of the converter unit connected with a protection coordination cable is returned. If
multiple MR-J5D_ are connected to the converter unit, "00000000h" is returned for the second and subsequent MR-J5D_.
8.40

[Converter regenerative load ratio (Obj. 2B49h)]

[Converter regenerative load ratio (Obj. 2B49h: 00h)]

Data Type
Access
I16
RO
Supported firmware version
ECT
C0
Description
The continuous effective load output of the converter unit is returned.
The effective value in relation to the rated output (= 100 %) is returned.
For the MR-J5-_G_/MR-J5W_-_G_, "0000h" is returned.
Mapping
Default
TxPDO
Mapping
Default
TxPDO
Range
Units
80000000h to
W
7FFFFFFFh
Range
Units
8000h to 7FFFh
%
8.39 [Unit power consumption 2 (Obj. 2B43h)]
Save
Parameter
Impossible
Save
Parameter
Impossible
8 Monitor Objects
8
97

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-j5w-g-n1Mr-j5-gMr-j5w-g