9.63

[One-touch tuning mode (Obj. 2D50h)]

[One-touch tuning mode (Obj. 2D50h: 00h)]

Data Type
Access
U8
RW
Supported firmware version
ECT
A5
Description
One-touch tuning command is returned and set. After one-touch tuning, the setting value automatically changes to "00h".
00h: One-touch tuning stop in progress
01h: Basic mode
02h: High mode
03h: Low mode
9.64

[One-touch tuning status (Obj. 2D51h)]

[One-touch tuning status (Obj. 2D51h: 00h)]

Data Type
Access
I8
RO
Supported firmware version
ECT
A5
Description
The one-touch tuning progress is returned. Regardless of whether one-touch tuning is properly completed or not, "100" is
returned at the completion.
Mapping
Default
Impossible
00h
Mapping
Default
Impossible
Range
Units
00h to 03h
Range
Units
0 to 100
%