8.27
[Number of tough drive operations (Obj. 2B28h)]
[Number of tough drive operations (Obj. 2B28h: 00h)]
Data Type
Access
U16
RO
Supported firmware version
ECT
A5
Description
The number of tough drive operations is returned.
8.28
[Internal temperature of amplifier (Obj. 2B2Ah)]
[Internal temperature of amplifier (Obj. 2B2Ah: 00h)]
Data Type
Access
I16
RO
Supported firmware version
ECT
A5
Description
The internal temperature of the servo amplifier is returned.
8.29
[Unit power consumption (Obj. 2B2Dh)]
[Unit power consumption (Obj. 2B2Dh: 00h)]
Data Type
Access
I16
RO
Supported firmware version
ECT
A5
Description
For the MR-J5-_G_/MR-J5W_-_G_, the unit power consumption is returned.
For the MR-J5D_, the power consumption of the converter unit connected with a protection coordination cable is returned. If
multiple MR-J5D_ are connected to the converter unit, "0000h" is returned for the second and subsequent MR-J5D_.
Mapping
Default
TxPDO
Mapping
Default
TxPDO
Mapping
Default
TxPDO
Range
Units
0000h to FFFFh
number of times
Range
Units
8000h to 7FFFh
°C
Range
Units
8000h to 7FFFh
W
8.27 [Number of tough drive operations (Obj. 2B28h)]
Save
Parameter
Impossible
Save
Parameter
Impossible
Save
Parameter
Impossible
8 Monitor Objects
8
93