10.7

[Modes of operation display (Obj. 6061h)]

[Modes of operation display (Obj. 6061h: 00h)]

Data Type
Access
I8
RO
Supported firmware version
ECT
A5
Description
The current control mode is returned.
Regarding the initial value, the value that is returned depends on the setting value of [Pr. PA01.0 Control mode selection] and
[Pr. PT01.2 Unit for position data]. Refer to "Selecting control mode (Modes of operation)" in the following manual.
MR-J5-G-N1/MR-J5W-G-N1 User's Manual (Communication Function)
Even if "0" is set for [Modes of operation (Obj. 6060h)], this object does not return "0".
Setting value
Description
0
No mode change/No mode assigned
1
Profile position mode (pp)
2
3
Profile velocity mode (pv)
4
Profile torque mode (tq)
5
6
Homing mode (hm)
7
8
Cyclic synchronous position mode (csp)
9
Cyclic synchronous velocity mode (csv)
10
Cyclic synchronous torque mode (cst)
-1
Test Operation mode: JOG Operation
-2
Test Operation mode: Positioning Operation
-4
Test Operation mode: DO forced output
-6
Test Operation mode: Machine analyzer
-9
Test Operation mode: Test Exit
*1
-10
Test Operation mode: Single-step feed
*1
-100
Jog mode (jg)
*1
-101
Point table mode (pt)
*1 Available on servo amplifiers with firmware version B8 or later.
Mapping
Default
TxPDO
Range
Units
Refer to the
following.
10.7 [Modes of operation display (Obj. 6061h)]