16
Point table Mode Objects
16.1

[Point table 001 (Obj. 2801h)]

[Point table 001 (Obj. 2801h: 00h)]

Data Type
Access
U8
RO
Supported firmware version
ECT
B8
Description
The total number of Sub Indexes (= 7) is returned.

[Point data (Obj. 2801h: 01h)]

Data Type
Access
I32
RW
Supported firmware version
ECT
B8
Description
Set the travel distance of the point table.
The setting range varies depending on the value of [Pr. PT01.2 Unit for position data].
[Pr. PT01.2]
0 (mm)
1 (inch)
2 (degree)
3 (pulse)
16 Point table Mode Objects
184
16.1 [Point table 001 (Obj. 2801h)]
Mapping
Default
Impossible
7
Mapping
Default
Impossible
0
Range
80000000h to 7FFFFFFFh (-2147483648 to 2147483647)
80000000h to 7FFFFFFFh (-2147483648 to 2147483647)
FFFA81C0h to 00057E40h (-360000 to 360000)
80000000h to 7FFFFFFFh (-2147483648 to 2147483647)
Range
Units
7 (fixed)
Range
Units
Refer to the
pos units
following.
Save
Parameter
Impossible
Save
Parameter
Possible