9.28
[Tension estimation value (Obj. 2C36h)]
[Tension estimation value (Obj. 2C36h: 00h)]
Data Type
Access
I32
RO
Supported firmware version
ECT
A5
Description
The estimated tension value used by the belt tension deterioration function is expressed in 0.1 N units.
Mapping
Default
Impossible
Range
Units
-2147483648 to
0.1 N
2147483647
9 Manufacturer Specific Control Object
9.28 [Tension estimation value (Obj. 2C36h)]