15.7 Parameter Window
Read-out from the driver
Communicates with the connected servo amplifier and reads the parameter settings from
the servo amplifier. If this mode is selected, parameter values will be reflected in the servo
amplifier as soon as they are changed.
Read from file
Refer to the parameter file (".prm5") that was edited previously. If communication is
performed with the servo amplifier, parameter values will be reflected in the servo amplifier
as soon as they are changed.
Read default
Reads the standard default settings of the servo amplifier that were saved during
installation. If communication is performed with the servo amplifier, parameter values will
be reflected in the servo amplifier as soon as they are changed.
2.
Select one of the three options above and click the [OK] button.
The Parameter window will be displayed.
3.
After changing the parameter settings, click the [EEP] button to write the parameter settings
to the EEPROM of the servo amplifier.
4.
Click the [×] button on the Parameter window to close the Parameter window.

15.7.3 Copying Parameters

Copies the parameters of a servo amplifier to servo amplifiers for other axes.
It is not possible to copy from A6N type to A5N type or from A5N type to A6N type.