12.4 General-purpose I/O
2.
Set up general-purpose IO parameters.
Select an IO parameter to be changed and then select a desired item from the drop-down
list.
3.
Select the "I/O Mapping" tab and set the correspondence (mapping) between the channel
and variable in the mapping setting pane.
Click the "Variable" column corresponding to the channel to be used by the program and
enter a variable name.
Clicking the mark in the "Mapping" column allows you to change the type of mapping.
● You can copy the variable name set in the Channel column.
Select a channel (CH0 or CH1) in the "Category Selection" column, right-click, and then select
[Copy] from the context-sensitive menu that is displayed. Next, select another channel, right-
click, and then select [Paste] from the context-sensitive menu that is displayed.
12.4.3 Setting Items of IO_Configuration Parameters
■
IO parameters
Setting item
General-purpose
input time constant
12-6
Setting item
Settings
Input time
None
constant
0.1 ms
0.5 ms
Default value
Description
None
Input time constant
WUME-GM1RTXOP-01