Panasonic GM1 User Manual page 508

Motion controller controller rtex
Hide thumbs Also See for GM1:
Table of Contents

Advertisement

12.6 High-speed Counter Function
● A total of 16 comparison match flags can be set separately for each comparison data item.
● Multiple comparison data items can be set for the same band.
● For details on how to set up parameters, refer to
Programmer".
Setting example for band comparison
Output setting example
Compa
Band comparison value
rison
Lower limit
data
0
+1,250
1
+3,750
2
+3,750
3
+6,250
4
+8,750
Behavior of comparison match flag during band comparison
12-46
Output
setting
Upper limit
2,500
Set
+5,000
Set
+7,500
Set
+7,500
Set
+500
Set
"12.6.2 Setting Parameters with GM
Compariso
Compariso
n match 0
n match 1
flag
flag
ON
OFF
OFF
ON
OFF
OFF
ON
ON
OFF
OFF
Compariso
Compariso
n match 2
n match 3
flag
flag
OFF
OFF
OFF
ON
OFF
ON
ON
ON
ON
OFF
WUME-GM1RTXOP-01