Forgetting Tools
Each tool can only be associated with a single qualifier at a time but learning a tool to another
qualifier does not automatically remove it from the previous qualifier. If you have moved or are
planning to move a tool from one EYFR03 to another, you should have the qualifier "forget" the
tool. To do so, press Forget on the Tool Configuration screen to remove the tool from the
qualifier. This will cause the qualifier to no longer respond to the tool and will make any
parameters using the tool and any groups or jobs using those parameters invalid. If you learn
AccuPulse in one-way mode "90" and want to relearn it in two-way mode "91", you must
"forget" the tool first. You cannot just "relearn".

Parameters

Selecting Parameters
Figure 22: Main Menu - Parameters
Figure 23: Choose Parameter screen
Soft keys
1. Select – Select the currently highlighted parameter to run and return to the Run screen. Only
available for selectable parameters.
2. Edit – Edit the currently highlighted parameter.
3. Copy – Selects the currently highlighted parameter to be copied to another location.
4. Exit [ESC] – Returns to the Main Menu screen.
The Choose Parameter screen shows all the parameters in the unit in a 10x10 grid. Parameters
may be highlighted by using the arrow keys to move the highlight to the desired parameter or
typing the number of the desired parameter. Only the parameters with tools assigned will show
their numbers on the grid. A selectable parameter will have a black number. A defined but not
selectable parameter will be shown in red. A parameter is defined when a tool number is
assigned to it. If the assigned tool number is an empty tool slot, because either no tool was ever
learned or the previous tool was forgotten, the parameter will become unselectable.
Because parameters 1-16 are locked to tools 1-16 respectively, they will be blank if the
associated tool slot is empty.