Panasonic GM1 User Manual page 485

Motion controller controller rtex
Hide thumbs Also See for GM1:
Table of Contents

Advertisement

Setting item
Counter upper limit
Counter lower limit
Specify count direction
Select count input
Count method
Input Z signal function setting
Control 0 signal function setting
Control 1 signal function setting
Default value
Input A signal/Input B signal
input time constant
Input Z signal input time
constant
Control signal input time
constant
WUME-GM1RTXOP-01
Settings
-2,147,483,647 to 2,147,483,647
-2,147,483,648 to 2,147,483,646
Count in normal direction / Count in reverse direction
Count signal
Internal clock 0.25 µs (4 MHz)
Internal clock 1.00 µs (1 MHz)
Internal clock 10 µs (100 kHz)
Internal clock 100 µs (10 kHz)
2-phase input 1 multiple / 2-phase input 2 multiple / 2-
phase input 4 multiple / Individual input 1 multiple /
Individual input 2 multiple / Direction detection input 1
multiple / Direction detection input 2 multiple
Not used
Reset operation at rising edge
Reset operation at falling edge
Positive logic reset operation
Negative logic reset operation
Preset operation at rising edge
Preset operation at falling edge
Positive logic preset operation
Negative logic preset operation
Not used
Positive logic enable operation
Negative logic enable operation
Positive logic enable operation, reset operation at
rising edge
Negative logic enable operation and reset operation at
falling edge
Positive logic enable operation and preset operation at
rising edge
Negative logic enable operation and preset operation
at falling edge
Not used
Positive logic enable operation
Negative logic enable operation
Overwrites the count value with the default value when
the power is turned ON
No input time constant / 0.1 µs (2 MHz) / 0.2 µs (1
MHz) / 0.5 µs (500 kHz) / 1.0 µs (250 kHz) / 2.0 µs
(100 kHz) / 10.0 µs (10 kHz)
No input time constant / 0.1 µs (2 MHz) / 0.2 µs (1
MHz) / 0.5 µs (500 kHz) / 1.0 µs (250 kHz) / 2.0 µs
(100 kHz) / 10.0 µs (10 kHz)
No input time constant / 2 µs / 5 µs / 10 µs / 20 µs / 50
µs / 100 µs / 500 µs / 1.0 ms / 2.0 ms / 5.0 ms / 10.0
ms
12.6 High-speed Counter Function
Default value
2,147,483,647
-2,147,483,648
Count in normal
direction
Count signal
2-phase input 1
multiple
Not used
Not used
Not used
0
2.0 µs (100 kHz)
2.0 ms
12-23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gm1 series