Behavior of comparison match flag during decrementation count
When the current value matches the comparison data, the comparison match flag behaves
according to the setting of "Subtraction set pattern" or "Subtraction reset pattern".
● For ring counters, comparison data can be set in an area including the lower and upper limits
where count values are rolled over.
Parameter settings for band comparison
Parameter setting procedure
1. Click Counter parameter>Counter (Ch0 or Ch1)>Comparison function, change the
"Select comparison function" parameter to "Band comparison", and execute "Set number of
comparison data".
2. Click Counter parameters>Counter (Ch0 or Ch1)>Comparison functio>Comparison
data and specify upper and lower limits for each comparison data item.
3. Set whether to turn ON or OFF the comparison match flag when the count value exists in
the zone (between the upper and lower limits).
4. Configure these settings for each comparison data item.
WUME-GM1RTXOP-01
12.6 High-speed Counter Function