Detection Scenarios
Root Causes
Possible CRU Replacements
Resolution
T071: Power Supply not present
Description
Detection Scenarios
Root Causes
Possible CRU Replacements
Resolution
T072: The system has reported an unmanaged fault
Description
Resolution
1. The loss of communications between the library and the
drive sled
2. The loss of communications between the drive sled
controller board and the drive brick.
1. Various hardware problems inside the drive sled.
2. Drive firmware problem
3. Drive sled firmware problem
4. Library communication firmware problem
5. Drive Sled Interface Board (DSIB) hardware problem
6. Loss of power to sled (DSIB 48 V fuse)
Tape Drive
v Update drive firmware (see "Updating Drive Firmware"
on page 8-13.
v Update library firmware (see "Updating Library
Firmware" on page 8-12.
v If the problem still exists, replace the drive sled (see
"Adding/Removing/Replacing a Drive Sled" on page
12-15).
The library can no longer detect the presence of a power
supply that was previously physically installed and
logically added to the system.
Regular polling between LCB and power supply checks for
presence of the power supply.
1. Power Supply has been physically removed after being
added to a powered ON system.
2. Hardware failure inside supply
3. Hardware failure in library side connector of other
electronics.
Power Supply
Perform "DR022: Power Supply Not Present" on page
11-41.
Library firmware has reported a problem that is not
associated with a specific ticket and corresponding
diagnostic resolution. This problem cannot be resolved
without escalation to tech support and engineering.
Perform "DR021: Contact Service" on page 11-41.
Chapter 11. Service Action Tickets (Txxx) and Diagnostic Resolutions (DRxxx)
11-27