Pass*/Fail* Results - Fluke Versiv Series Technical Reference Handbook

Hide thumbs Also See for Versiv Series:
Table of Contents

Advertisement

Versiv Series Cabling Certification Product Family
Technical Reference Handbook

PASS*/FAIL* Results

A result shows an asterisk when measurements are in the tester's
accuracy uncertainty range (Figure 36) and the asterisk is required
by the selected test limit. These results are marginal.
A PASS* shows that the cable's performance is
satisfactory. If a cable must get a PASS result to agree with
your requirements for quality, identify and correct the
problems with the cable and do the Autotest again.
Usually, a FAIL* is not a satisfactory result. The tester
shows a FAIL for the overall result. Identify and correct the
problems with the cable and do the Autotest again.
Tester's accuracy
uncertainty
range
Limit
98
PASS*
Figure 36. PASS* and FAIL* Results
PASS
PASS*
FAIL*
FAIL
GPU87.EPS