Fluke Versiv Series Technical Reference Handbook page 644

Hide thumbs Also See for Versiv Series:
Table of Contents

Advertisement

Versiv Series Cabling Certification Product Family
Technical Reference Handbook
DSX-8000 Level 2G Accuracy Performance Parameters
Parameter
Baseline Field Tester
Source Match
Return loss of
Termination
1000 to 2000 MHz:
608
per IEC Guidelines (continued)
1 to 1000 MHz:
21 - 9log(f/100),
25 dB maximum
12 dB
Field Tester with
Level 2G
Permanent Link
Adapter
1 to 1000 MHz: 20 dB
1000 to 2000 MHz:
35 - 15log(f/100)
1 to 1000 MHz:
19 - 9log(f/100),
25 dB maximum
1000 to 2000 MHz: 10 dB
Field Tester with
Level 2G Channel
Adapter

Hide quick links: