To Clean the Optical Connectors on the Modules

To clean the optical connectors on the modules, first use the
procedure given under "To Clean Bulkhead Connectors".
If a connector is very dirty or the procedure above does not make
it clean, use this procedure:
Unscrew the adapter on the connector.
1
Clean the ferrule or photodiode lens with a dry, optical-grade
2
wipe made for fiber optic connectors.
Use a video probe to inspect the connector. If necessary, clean
3
and inspect the connector again.
If the connector stays dirty, use a wipe that is moist with
4
optical-grade solvent to clean the endface. Dry the ferrule
with a dry wipe.
If the OTDR Port Connection Quality gauge for
the OptiFiber Pro module stays in the Poor range
after you clean the OTDR connector, remove the
adapter from the module and inspect the adapter
for damage. Make sure that the white plastic ring
inside the center tube shows no damage.

To Clean Fiber Adapters

At regular intervals, clean fiber adapters with a swab and fiber
optic solvent. Dry with a dry swab.