Versiv Series Cabling Certification Product Family
Technical Reference Handbook

Delay Skew

Parameter
Range
Resolution
Accuracy

DC Loop Resistance

Parameter
Range
Resolution
Accuracy
Overload
Recovery Time

DC Resistance Unbalance

Parameter
Resolution
Accuracy for unbalance
within a pair
Accuracy for unbalance
between pairs
HDTDX Analyzer Specifications for Cables <100 m (328 ft)
Parameter
Distance accuracy
Distance resolution
616
Twisted Pair Cabling
0 ns to 100 ns
1 ns
 10 ns
DSX-5000
0  to 540 
0.1 
 (1  + 1 %)
Less than 10 minutes to rated accuracy following an
overvoltage. Referencing is required after repeated or
prolonged overvoltage.
Twisted Pair Cabling
0.005 
± (0.025 + 0.3% of loop resistance)
±(0.025 + 0.3% of mean loop resistance for the
two pairs)
 (0.3 m (1 ft) + 2 % distance)
0.1 m or 1 ft
DSX-8000
0  to 540 
0.01 
 (0.5  + 1 %)
Twisted Pair Cabling