Chapter 19: Custom Media and Test

Make a Custom Copper Cable Type

If a twisted pair or coaxial cable installation has a cable type that
is not in the list of types in the tester, you can make a custom
cable type for the job. A custom cable type has these settings:
Custom cable name
Standard cable type used for default values
NVP (nominal velocity of propagation)
You can make up to 20 custom cable types. The tester keeps
custom cable types with the other cable types in the main tester
(not in the module). The names of custom cable types have an
asterisk (*) at the start and end.
Use the values specified by the cable manufacturer to make the
custom cable type.
To make a custom cable type
On the home screen, tap the test setup panel.
1
On the CHANGE TEST screen, tap a copper test, then tap EDIT.
2
You must select a test before you make a custom
cable type, but you can use the cable type in any
test that supports the category of the cable.
On the TEST SETUP screen, tap Cable Type, tap MORE, tap
3
Custom, then tap MANAGE.
On the MANAGE CUSTOM screen, tap the Create panel.
4
Note
Limits
-continued-