Step 3: Turn Off The Auto Save Function; Step 4: Do An Autotest; Step 5: Look At The Results - Fluke Versiv Series Technical Reference Handbook

Hide thumbs Also See for Versiv Series:
Table of Contents

Advertisement

Versiv Series Cabling Certification Product Family
Technical Reference Handbook
If the correct outlet configuration does not show, tap Outlet
Configuration. On the OUTLET CONFIG screen, tap the
correct configuration, then tap USE SELECTED.
AC Wire Map: This setting lets you do tests on links
connected through midspan PoE (Power over Ethernet)
devices. For this tutorial, make sure this setting is Off.
On the TEST SETUP screen, tap SAVE.
2-5
On the CHANGE TEST screen, tap the twisted pair test you
2-6
made, then tap USE SELECTED.
For more information on settings, see "Settings for Twisted Pair
Tests" on page 84.

Step 3: Turn Off the Auto Save Function

For this tutorial, you will manually save the test results.
On the home screen, tap the Next ID panel.
3-1
On the CHANGE ID screen, tap the Auto Save control to make
3-2
it show Off.
Tap DONE.
3-3

Step 4: Do an Autotest

Attach the channel adapters to the main and remote testers.
4-1
Turn on both testers, then connect a twisted pair cable
4-2
between the adapters.
Tap TEST on the main tester or press  on the main or
4-3
remote tester.

Step 5: Look at the Results

The tester shows the Autotest results in three formats (Figure 11):
40

Hide quick links: