Fluke Versiv Series Technical Reference Handbook page 325

Hide thumbs Also See for Versiv Series:
Table of Contents

Advertisement

The result exceeds the limit.
The result is within the limit.
The selected test limit does not have a limit for the test.
(see the note on the next page)
To see the results, limit, and margins for the fiber, tap the
window.
The Autotest in Far End Source mode does not
show a PASS/FAIL result, limit, or margin if the
selected test limit uses fiber length to calculate
loss. An example of such a limit is the TIA-568C
Fiber Backbone limit. The tester does not measure
length in Far End Source mode.
The settings the tester used for the test.
The dashed lines are around the connectors and fiber that are
included in the loss and length results. Gray connectors and
fibers are not included because you used them to set the
reference.
Connector icons show the number you entered for the TOTAL
CONNECTIONS setting on the No. of Connectors/Splices screen
(Figure 108 on page 257). For Figure 122, the TOTAL
CONNECTIONS setting is 1.
The round icon shows the number of splices entered for the
SPLICES setting on the No. of Connectors/Splices screen.
To see help for the screen, tap
When more than one button shows at the bottom of the screen,
the tester highlights one in yellow to recommend which one to
tap. See "Buttons to Do Tests and Save Results" on page 61.
Chapter 9: Certify Fiber Cabling
Autotest in Far End Source Mode
Note
.
289