Fluke Versiv Series Technical Reference Handbook page 426

Hide thumbs Also See for Versiv Series:
Table of Contents

Advertisement

Versiv Series Cabling Certification Product Family
Technical Reference Handbook
This button shows with bi-directional SmartLoop results
and bi-directional OTDR results from single fibers. Tap this
button to see results from each direction (End 1 or End 2) or
the averaged results (
This button shows if you do a bi-directional test on a single
fiber, but the tester does not calculate averaged results. This can
occur for example if the distance to the end was not the same
in both directions or if a span was defined when you did the
test. Tap this button to see results from each direction (End 1
or End 2). To remove the span definition, tap Tools, Span, then
tap Delete.
The event editing function lets you edit loss events. See
"How to Edit a Loss Event" on page 481.
This line shows which results are on the display. Use the
selection buttons (
Overall Loss: The average loss of the two directions.
Fiber Length: The longest length of the two directions.
PASS/FAIL: The overall result for the fibers.
PASS: The averaged results passed. It is possible for one or
both directions to have FAIL results, while the overall
result is PASS.
FAIL: The averaged results failed.
The tester does not use the bi-directional average
results in the calculation for the % Tested that
shows on the home screen.
390
).
and
) to see other results.
Note