To Set Up An Otdr Test For The Project - Fluke Versiv Series Technical Reference Handbook

Hide thumbs Also See for Versiv Series:
Table of Contents

Advertisement

3-7. On the TEST SETUP screen, make sure the Test Type shows
Smart Remote. If it does not, tap Test Type, then tap Smart
Remote.
3-8. On the TEST SETUP screen, select and change the test
settings as necessary for the loss/length test.
For this tutorial, set Bi-directional to Off.
For information about other loss/length test settings, see
"Settings for Loss/Length Tests on Fiber" on page 252.
3-9. When you have completed your selections for the Smart
Remote test, tap SAVE on the TEST SETUP screen.

To set up an OTDR test for the project

3-10. On the PROJECT screen, tap NEW TEST.
3-11. If the TEST SETUP screen does not show an OptiFiber Pro
module, tap Module.
If a module is not attached, the MODULE screen shows.
On the MODULE screen, tap an OptiFiber Pro OTDR module.
3-12. On the TEST SETUP screen, make sure the Test Type shows
Auto OTDR. If it does not, tap Test Type, then tap Auto
OTDR.
3-13. On the TEST SETUP screen, select and change the test
settings as necessary for the Auto OTDR test. For
information about OTDR test settings, see "Settings for
OTDR Tests" on page 310.
For this tutorial, set Launch Compensation to Off.
3-14. When you have completed your selections for the Auto
OTDR test, tap SAVE on the TEST SETUP screen.
Chapter 17: Use Projects
Tutorial: Make a New Project
521

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

VersivVersiv 2Dsx-8000Dsx-5000Cfp2-100-q-int

Table of Contents