How to Make ID Sets

There are three methods you can use to make ID sets:
Make sets of sequential IDs on the tester.
Make sets of sequential IDs in LinkWare PC or LinkWare Live
Professional software, download them to the tester, then
import them into a project on the tester. See "Import an ID
Set into a Project" on page 552. These sets can include non-
sequential IDs.
Make an ID set in a LinkWare Live project, then sync the
project to the tester. See the help in LinkWare Live for details.
To make a set of sequential IDs, you enter the first and last ID in
the set. The tester (or LinkWare software) increments the letters
and numbers in the first ID from right to left to make a set of IDs
that starts with your first ID and ends with your last ID. Special
characters, letters with accents, and letters that are the same in
the first and last IDs do not increment.
For example, here is an installation with eight fibers:
Two rooms: rooms 17 and 18
Two fiber cables in each room: cables 1 and 2
Two fibers in each cable: fibers A and B
You can make this ID set for the installation:
First ID: ROOM 17 FIBER 1A
Last ID: ROOM 18 FIBER 2B
These IDs make this set of eight IDs:
ROOM 17 FIBER 1A
ROOM 17 FIBER 1B
ROOM 17 FIBER 2A
548