Fluke Versiv Series Technical Reference Handbook page 643

Hide thumbs Also See for Versiv Series:
Table of Contents

Advertisement

DSX-8000 Level 2G Accuracy Performance Parameters
Parameter
Baseline Field Tester
Residual NEXT
90 – 20 log(f/100)
(measured to 90 dB
Residual FEXT
80 - 20 log(f/100)
(measured to 85 dB
Output Signal
Balance
40 - 20 log(f/100)
(measured to 40 dB
600 to 2000 MHz:
Common
Mode
40 - 20 log(f/100)
Rejection
(measured to 40 dB
600 to 2000 MHz:
Reflection
Tracking
Directivity
30.7 - 9log(f/100),
30 dB maximum
DSX-8000 CableAnalyzer Module Specifications
per IEC Guidelines (continued)
1 to 2000 MHz:
maximum)
1 to 2000 MHz:
maximum)
1 to 600 MHz:
maximum)
24.4 dB
1 to 600 MHz:
maximum)
24.4 dB
1 to 2000 MHz:
Chapter 21: Specifications
Field Tester with
Level 2G
Permanent Link
Adapter
1 to 2000 MHz:
85 - 20 log(f/100)
(measured to 90 dB
maximum)
1 to 2000 MHz:
70 - 20 log(f/100)
(measured to 85 dB
maximum)
1 to 600 MHz: 37 - 20 log(f/100)
(measured to 40 dB maximum)
600 to 2000 MHz: 21.4 dB
1 to 600 MHz: 37 - 20 log(f/100)
(measured to 40 dB maximum)
600 to 2000 MHz: 21.4 dB
 0.5 dB
1 to 300 MHz:
28.7 - 9log(f/100), 30 dB maximum
Field Tester with
Level 2G Channel
Adapter
1 to 500 MHz:
64 - 20 log(f/100)
(measured to 90 dB
maximum)
500 to 2000 MHz:
50.0206 - 45log(f/100)
1 to 2000 MHz:
43.1 - 20 log(f/100)
(measured to 85 dB
maximum)
-continued-
607

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

VersivVersiv 2Dsx-8000Dsx-5000Cfp2-100-q-int

Table of Contents