Ac Wire Map Results - Fluke Versiv Series Technical Reference Handbook

Hide thumbs Also See for Versiv Series:
Table of Contents

Advertisement

Versiv Series Cabling Certification Product Family
Technical Reference Handbook
Patch cord
from hub
or switch
Start
channel
Tester with
channel adapter
Figure 72. Channel Connections Through a PoE Device

AC Wire Map Results

AC wire map results are similar to the wire map results shown in
Chapter 3. In some cases, the fault information given by AC wire
maps is less specific. For example, if a wire is shorted to a wire in
another pair, the AC wire map shows all four wires shorted. This
occurs because the AC electrical characteristics of some faults
prevent some types of measurements.
Figures 73 and 74 show examples of AC wire map screens.
When the tester cannot show the wire map because it has
multiple faults, it shows a list of the faults (see Figure 74).
162
Horizontal cabling
Patch
panels
Midspan
device
Hub or switch
Optional
consolidation
point
Wall
outlet
Patch cord
from PC
End
channel
Remote with
channel adapter
GPU95.EPS

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

VersivVersiv 2Dsx-8000Dsx-5000Cfp2-100-q-int